SDL -SDLT
16Pagine

{{requestButtons}}

Estratti del catalogo

SDL -SDLT - 1

SDL - SDLT Shut-off - Gas Shut-off Damper

Aprire il catalogo a pagina 1
SDL -SDLT - 2

Shut-off - Gas Shut-off Damper Marine - Oil & Gas Industry Quality Our Quality Management System has been certified in accordance with the standard ISO 9001 : 2008. Our company is monitored by RINA, a member of iQNet Euro-pean network, and is appointed with the quality management system certificate for the fields of activity of design and production of filter, filter systems and air dis-tribution components for HVAC systems. Environment Being involved with the production of equipment for indoor en-vironment control and air filtra-tion, it is natural for SagiCofim to consider the...

Aprire il catalogo a pagina 2
SDL -SDLT - 3

Shut-off - Gas Shut-off Damper SagiCofim SDL - SDLT Shut-off and Gas Shut-off Dampers are used to stop the air flow or to let the passage of the air within ductworks or behind air intake grilles for ships and offshore installation. They can be required for safe-ty reasons as a fire protection component as they isolate or open sections of air condition-ing or ventilation systems in case of fire and gas on board. Shut-off and Gas Shut-off Dampers are available with remote electrical or pneu-matic rotating actuators or with manual command, both standard or ATEX version. If fitted with an...

Aprire il catalogo a pagina 3
SDL -SDLT - 4

Shut-off - Gas Shut-off Damper General features Shut-off dampers & Gas Shut-off dampers * Dampers can be supplied on request with special dimensions by multiple welded arrangement. With manual control With electrical control

Aprire il catalogo a pagina 4
SDL -SDLT - 5

Shut-off - Gas Shut-off Damper Marine - Oil & Gas Industry SciCjiCofilTI Damper operating range: ATEX area - 20 ° C ^ t s + 50 ° C - Vmax 15 m/s - Pmax 3000 PaSAFE area - 20 ° C ^ t ^ + 70 ° C - Vmax 25 m/s - Pmax 3000 Pa Damper components materials Silicone seals and thin blades only for models SDLT

Aprire il catalogo a pagina 5
SDL -SDLT - 6

Shut-off - Gas Shut-off Damper SagiCof’ im Dimensions of flanges and drilling 4- Fixed holes at corner o Intermediate holes

Aprire il catalogo a pagina 6
SDL -SDLT - 7

Shut-off - Gas Shut-off Damper SagiCofim Damper weights [Kg] Damper weights [Kg] H W [width] Average values valid for all standard types (approx. ± 5%) Values in the table refer to the standard material manufcturing types. Different material manufacturing does not have significant variance to the above mentioned values. Controls and actuators weights are not included.

Aprire il catalogo a pagina 7
SDL -SDLT - 8

Shut-off - Gas Shut-off Damper SagiCofim Torque requirements (Nm) for actuating systems selection Damper torque Note: for SDL model, actual required torque value can be up to 20% lower than the above mentioned values.

Aprire il catalogo a pagina 8
SDL -SDLT - 9

Shut-off - Gas Shut-off Damper SDL - SDLT Performances Pressure drop and noise level 55 • Max noise level: 60 dB(A) • Standard pressure drop: 6 Pa With damper fully open and air speed of 5 m/s at maximum rate. With damper fully open and air speed of 15 m/s at maximum rate. SDLT gas leakage according to EN1751 10000 Leakage test across closed blades Positive pressure Negative pressure Leakage test for casing Positive pressure

Aprire il catalogo a pagina 9
SDL -SDLT - 10

Shut-off - Gas Shut-off Damper SagiCofim Damper controls Type E Electrical actuator Type X Electrical ATEX zone approved actuator Shut-off dampers and Gas Shut-off dampers can be provided with many different combinations of actuators - junction boxes - limit switches in order to fulfil to all technical specification or custom-er demand: nominal actuator torque (5, 10, 15, 30 ... Nm); voltage input range from 24V to 230 V AC/DC; plastic, painted aluminium, gal-vanized steel or AISI 316 actuator case; on/off, on/off spring return, modulating actuator with or wi-thout integrated micro...

Aprire il catalogo a pagina 10
SDL -SDLT - 11

Shut-off - Gas Shut-off Damper SagiCofim Type of installation * Actuator protrusion only. For total protrusion, please consider also piate protrusion. Electric actuators are fixed to le-vers protection carter by an uni-versal piate (galvanized steel or AISI 316). This plate is designed to fix differ-ent type of actuators only switch-ing its own orientation or using different fixing holes. Different type of installation: • BFL type through fixing holes 3, with a 180° plate rotation respect to plate position as shown in the example; • LF / BFN type through fixing holes 4, with a 180° plate...

Aprire il catalogo a pagina 11
SDL -SDLT - 12

Shut-off - Gas Shut-off Damper SDL - SDLT Damper controls Type P Pneumatic actuator SDL - SDLT Shut-off dampers and Gas Shut-off dampers can be equipped with rotating pneumatic actuators (6 - 10 bar) and additional accessories such as solenoid valves and limit switches (mechanical, magnetic or inductive type). Actuator can be made of PTFE coated aluminium, painted steel, stainless steel or composite. Fail CLOSE A typical pneumatic system is composed by: • a rotating piston with a specific even number of springs (according to the model); • a 3 - ways solenoid valve; • a manometer and a...

Aprire il catalogo a pagina 12
SDL -SDLT - 13

Shut-off - Gas Shut-off Damper Marine - Oil & Gas Industry SaCJlCofim * Piston available in 3 sizes 15 Nm - 43 Nm - 132 Nm * Piston available in 3 sizes 15 Nm - 43 Nm - 132 Nm Both available for ATEX version. Custom configuration available. Extra and accessories • Check valve • In line filter • Manual by-pass valve • Heating cable • Manual override with detachable clutch

Aprire il catalogo a pagina 13
SDL -SDLT - 14

Shut-off - Gas Shut-off Damper SagiCofim Damper controls Type C 22 - Manual drive This damper version is provided with a control handle (C22). SDL or SDLT + C22 can be used also as a balancing damper; in fact the handle can be fixed in all different positions from fully open to fully closed. A safety clamp blocks the handle in the selected position. Maintenance procedures Mechanical couplings and electri-cal connections are tested before shipping. Maintenance cadence depends by the dampers features (material) and the location where they are installed (fresh air inlet or exhaust duct) During...

Aprire il catalogo a pagina 14
SDL -SDLT - 15

Shut-off - Gas Shut-off Damper Marine - Oil & Gas Industry SciCjiCofilTI References Shipyards Barreras (Spain) Cantieri Apuania (Italy) Ferrol (Spain) Fincantieri (Italy) Flender Werft (Germany) Jurong (Singapore) Keppel Fels (Singapore) Lloyd Werft (Germany) Meyer Werft (Germany) Navantia (Spain) Rosetti Marino (Italy) Sembawang (Singapore) SMOE (Singapore) STX France (France) T. Mariotti (Italy) Owners Carnival Corsica Ferries Costa Crociere Cunard Finnlines Grimaldi Group Holland America Line Marina Militare Italiana Minoan Lines Norwegian Cruise Line P&O Radisson Seven...

Aprire il catalogo a pagina 15

Tutti i cataloghi e le schede tecniche SagiCofim

  1. LS-KS

    1 Pagine

  2. VLI-DD VLI-DDT

    2 Pagine

  3. SA SA - LF

    2 Pagine

  4. LMG - KMG

    1 Pagine

  5. SIGMA

    8 Pagine

  6. AH-AS

    1 Pagine

  7. SIGMA-BETA

    4 Pagine

  8. PDP

    1 Pagine

  9. PDP

    8 Pagine

  10. MPS

    2 Pagine

  11. PK

    3 Pagine

  12. JD

    3 Pagine

  13. FLG

    2 Pagine

  14. CANISTER

    4 Pagine

  15. LYRA

    12 Pagine

  16. IQID

    8 Pagine

  17. NOVAII

    24 Pagine

  18. WEGAII

    20 Pagine

  19. QVFH

    8 Pagine

  20. Vaporstream

    3 Pagine

  21. HUMIDI-TECH

    1 Pagine

  22. ES 4

    2 Pagine

  23. NORDMANN ES4

    4 Pagine

  24. AT 4

    2 Pagine

  25. NORDMANN AT4

    6 Pagine

  26. NORDMANN

    5 Pagine

  27. CARBO

    1 Pagine

  28. GAMMA

    12 Pagine

  29. CAP

    1 Pagine

  30. CANISTER

    8 Pagine

  31. CT/CTA

    6 Pagine

  32. CT

    1 Pagine

  33. SAF

    1 Pagine

  34. CAB - PT

    1 Pagine

  35. FILTRA-PAK

    12 Pagine

  36. DIF OT_LS

    8 Pagine

  37. DIF O.T.

    8 Pagine

  38. DUG-B_DUG-A

    2 Pagine

  39. INER-ST

    8 Pagine

  40. SMBA

    2 Pagine

  41. SFD-SFDT

    16 Pagine

  42. PFI -PFM-PFOM

    1 Pagine

  43. PFA6/6/7/8/9

    1 Pagine

  44. PFA/4-PFA/5

    1 Pagine

  45. MULTIMOD

    1 Pagine

  46. MODULO

    1 Pagine