video corpo

FDR AcSelerate
6Pagine

{{requestButtons}}

Estratti del catalogo

FDR AcSelerate - 1

F DR A c Seler at e Spec if ic ati o ns X-ray system Collimator Detector • Line voltage connection: 400V 3~(3N~), 480V 3~ ±10% (50Hz/60Hz) • Power consumption: 110kVA • Copper filter: 0.1mm, 0.2mm, 0.3mm • Rotation: ±45degree • Square collimation Manual / Motorized • Direct conversion method Flat Panel Detector • Dimensions: 17” ✕ 17” (43.2 ✕ 43.2cm) single panel: • Pixel size: 150um • Resolution: 2880 ✕ 2880 • Density resolution: 16bit • Panel cooling method: Fan cooled system Ceiling Tube support Table • Fully motorized 5 axes celling tube support • Vertical travel range: 175cm • Minimum focus-ceiling distance: 89cm • Tube rotation alpha/beta: alpha: ±135degree beta: 340degree • Tomography application • Automatic positioning • Tabletop size: 850 ✕ 2400mm • Table height: 550 to 930mm • Travel range: transverse: ±150mm longitudinal: ±600mm • Detector travel range: 630mm • Max. table load: 250kg • Automatics synchronization function • Accessories: Hand control (table operation and collimation control) Patient hand grips Lateral cassette holder* X,Y and Z foot control* X and Y foot control strip type* Compression belt* Tabletop mattress* Generator • High frequency generator • Output: 80kW • Exposure voltage: 40 to 150kVp • mA range: 10 to 1000mA • AEC (stand/table): 3 fields ion-chamber • DAP (inside collimation): option X-Ray Tube Console Advance • High performance PC • Monitor: 17”color TFT monitor (1280 ✕ 1024 display matrix) • Image preview: min. 2sec or less • Completion of Image processing: min. 4sec or less • DICOM functions* • Image Intelligence™* *option Stand • Focal spot: 0.6/1.0mm • Anode heat storage capacity: 600kHU (445kJ) • Anode heat dissipation rate: max 125kHU/min • Capacity of the small/large focus: 32 / 72kW • Target angle: 12degree • Total filtration: 2.5mmAl • Travel range (central beam - floor): 390 to 1900mm • Tilting angle: -20 to 90degree • Automatics synchronization function • Accessories: Hand control (collimation control) Patient grips (stretch and side hand grip) Cassette holder* Dimensions 4000 (158) Unit mm (in.): X-movement max 3350 (132) Standard 4m rail The new pinnacle in diagnostic imaging from Fujifilm. 4000 (158) 890-2640 (35-104) ±135˚ 340˚ Y-movement max 3160 (124) Standard 4m rail 610 (24) 550–930 (22–37) 850 (33) 2005 (79) 466.5 (18) 2313 (91) 600 (24) *Optional Rail of 4000mm ✕ 5000mm 2400 (95) 874(34) FDR AcSelerate (Model: FDR200) This equipment is a Class 2 laser product (IEC60825). Specifications are subject to change without notice. All brand names or trademarks are the property of their respective owners. All products require the regulatory approval of the importing country. For details on their availability, contact our local representative. http://www.fujifilm.com/products/medical/ 26-30, NISHIAZABU 2-CHOME, MINATO-KU, TOKYO 106-8620, JAPAN http://www.fujifilm.com/products/medical/ Ref. No. XB-968E (SK·09·09·F1120·F9711) Printed in Japan ©2009 FUJIFILM Corporation

Aprire il catalogo a pagina 1
FDR AcSelerate - 2

Welcome to the X-ray room of the future! A streamlined solution with dynamic speed and sharp images. Ever since the release of the first digital radiology system (FCR101) in 1983, Fujifilm has maintained its position as the leader in digital radiography images through its impressive quality, corporate endeavors, and commitment to customer satisfaction. Building upon our longstanding digital expertise and our superior diagnostic image processing technology we have accumulated over the years, Fujifilm has developed a new Flat Panel Detector (FPD), offering remarkably high X-ray conversion...

Aprire il catalogo a pagina 2
FDR AcSelerate - 3

Direct Conversion FPD – the revolutionary flat panel from Fujifilm It provides sharper and clearer diagnostic images to the medical efficiency scene using the high conversion efficiency of its innovative amorphous selenium technology. It has also overcome past limitations associated with the durability and temperature control of traditional Direct Conversion systems, as it only needs an air-cooling system. DIRECT CONVERSION FPD Image Intelligence™ – Over 25 years of expertise in medical imaging Image Intelligence Intelligence™ from Fujifilm is an integration of various digital...

Aprire il catalogo a pagina 3
FDR AcSelerate - 4

A new age with amorphous selenium (a-Se) Our newly developed direct conversion FPD is at the heart of AcSelerate, providing high conversion efficiency (see right diagram). It allows more effective use of the X-ray energy and offers high quality images with enhanced MTF and DQE, but with reduced radiation dose. Lifespan and temperature control limitations, seen with traditional flat panels, have been greatly improved and our FPD offers superb durability whilst utilising a simple air-cooling system. Direct conversion vs Indirect conversion With indirect conversion, X-rays are initially...

Aprire il catalogo a pagina 4
FDR AcSelerate - 5

AcSelerate has been ergonomically designed, not only for the technologist, but also for the patient. 80 kW High Voltage Generator Light-weight Ceiling Suspension System Vertical movement range 1750mm 1900 mm 340˚ The lightweight ceiling suspension system and tube head provide smooth movement to any position, to any angle and to any height within the examination room. The support features an extended range of vertical movement, 1750mm, which allows for easy examination of the lower extremities. 1750mm Tilting Upright X-ray Stand ±135˚ Wide range of movement for various examinations 930mm...

Aprire il catalogo a pagina 5
FDR AcSelerate - 6

F DR A c Seler at e Spec if ic ati o ns X-ray system Collimator Detector • Line voltage connection: 400V 3~(3N~), 480V 3~ ±10% (50Hz/60Hz) • Power consumption: 110kVA • Copper filter: 0.1mm, 0.2mm, 0.3mm • Rotation: ±45degree • Square collimation Manual / Motorized • Direct conversion method Flat Panel Detector • Dimensions: 17” ✕ 17” (43.2 ✕ 43.2cm) single panel: • Pixel size: 150um • Resolution: 2880 ✕ 2880 • Density resolution: 16bit • Panel cooling method: Fan cooled system Ceiling Tube support Table • Fully motorized 5 axes celling tube support • Vertical travel range: 175cm • Minimum...

Aprire il catalogo a pagina 6

Tutti i cataloghi e le schede tecniche FUJIFILM Europe

  1. FDR Nano

    5 Pagine

  2. FCR PRIMA T2

    3 Pagine

  3. SX800

    8 Pagine

  4. DRI-CHEM NX700

    4 Pagine

  5. FDR Go PLUS

    5 Pagine

  6. FVS-1000

    4 Pagine

  7. FCT Speedia

    7 Pagine

  8. FCT Speedia HD

    7 Pagine

  9. Amulet F

    4 Pagine

  10. FCRGo2

    3 Pagine

  11. RX Evo F

    2 Pagine

  12. FDR AcSelerate

    6 Pagine

  13. fcr xg5000

    3 Pagine

  14. FCRView

    4 Pagine

  15. PRIMA Series

    4 Pagine

  16. VELOCITY Tfp

    3 Pagine

  17. VELOCITY Ufp

    3 Pagine

  18. FCR VELOCITY T

    3 Pagine

  19. FCR CAPSULA X

    2 Pagine

  20. FCR PRIMA Tm

    3 Pagine

  21. FCR PRIMA II

    4 Pagine

  22. FCR PRIMA T2

    2 Pagine

  23. DRYPIX PRIMA

    3 Pagine

  24. DRYPIX7000

    4 Pagine

  25. DRYPIX Plus

    2 Pagine

  26. CAPSULA XLII

    3 Pagine

  27. FCR PROFECT CS

    3 Pagine

  28. FCR VELOCITY U

    3 Pagine